Schneider Electric On-delay timing relay - 0.1 s..100 h - 2 OC, REXL2TMP7
Excl. Tax
Excl. Tax
All Sellers
Seller | Price | Delivery | Shipping Cost | ||
---|---|---|---|---|---|
View Seller Profile
B2B Network
|
|
Shipping Cost
|
No sellers found for this product.
Schneider Electric On-delay timing relay - 0.1 s..100 h - 2 OC, REXL2TMP7
Excl. Tax
Excl. Tax
Description
Product Details
Activity | IDSIG |
---|---|
Resistance to electrostatic discharge | 6 kV in contact conforming to EN/IEC 61000-4-2 level 3, 8 kV in air conforming to EN/IEC 61000-4-2 level 3 |
Price | AEDÂ 203.23 |
Pincode Group | default |
Part Number | REXL2TMP7 |
Rated current | 5 A AC |
[Uc] control circuit voltage | 230 V |
[Ui] rated insulation voltage | 250 V conforming to IEC 255 Group C, 250 V conforming to VDE 0010 |
[Us] rated supply voltage | 230 V AC 50/60 Hz |
ambient air temperature for storage | -40-70 °C |
connections - terminals | screw connectors |
contacts material | cadmium free |
dielectric strength | 2 kV for 1 mA/1 minute at 50 Hz conforming to EN/IEC 60601-1, 2 kV for 1 mA/1 minute at 50 Hz conforming to EN/IEC 61812-1 |
fixing mode | plug-in (socket) |
IP degree of protection | IP50 conforming to IEC 60529 |
maximum switching capacity | 4 x 5 A |
mechanical durability | 10000000 cycles |
minimum switching current | 100 mA |
net weight | 0.05 kg |
product certifications | UL, cUL |
product or component type | single function relay |
range of product | Harmony Timer Relays |
relative humidity | 95-95 % without condensation conforming to IEC 60068-2-6 |
contacts type and composition | 2 C/O |
Reset time | 250 ms after time delay, on de-energisation, 50 ms during time delay, on de-energisation |
Immunity to microbreaks | 5 ms |
Power consumption in VA | 3 VA |
Disturbance radiated/conducted | class B conforming to EN 55022 (EN 55011 group 1) |
Resistance to electromagnetic fields | 10 V/m conforming to EN/IEC 61000-4-3 level 3 |
Surge withstand | 2 kV conforming to EN/IEC 61000-4-5 level 3 |
Resistance to fast transients | 2 kV conforming to EN/IEC 61000-4-4 level 3 |
Voltage range | 0.85...1.15 Us |
Temperature drift | 0.05 %/°C |
Creepage distance | 4 kV/3 conforming to IEC 60664-1 |
Voltage drift | +/- 0.2 %/V |
Time delay range | 10...100 h, 1...10 min, 1...10 h, 0.1...1 s, 6...60 min, 6...60 s, 1...10 s |
Output type | relay |
Time delay type | A |
Repeat accuracy | +/- 0.5 % |
Discrete output type | relay |
Setting accuracy of time delay | 10 % at full scale at 25 °C conforming to EN/IEC 61812-1 |
Functionality | on-delay timing |
Component name | REXL |
Immunity to radioelectric fields | 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 level 3 |
Immunity to voltage dips | >= 95 % / 1 s conforming to EN/IEC 61000-4-11, 30 % / 10 ms conforming to EN/IEC 61000-4-11, 60 % / 100 ms conforming to EN/IEC 61000-4-11 |
Output overvoltage protection | 2 J |
Temporary permissible current | 10 A for < 10 s |
vibration resistance | 0.35 mm (f= 10-55 Hz) conforming to IEC 60068-2-6 |
ambient air temperature for operation | -20-60 °C |
standards | EN/IEC 60601-1, 89/336/EEC, EN 61000-6-2, EN 50081-2, EN/IEC 61812-1, 73/23/EEC, EN/IEC 60601-2, 93/68/EEC |
local signalling | 1 LED (red) for output in operation, 1 LED (yellow) for power ON |
Electrical Durability | 100000 cycles at 250 V AC resistive |