Level control relay RM22-L - 24..240 V AC/DC - 2 C/O

RM22LA32MR
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Description

How to Video

Promotional Video

Product Details

Activity IDSIG
Price AED 463.57
Pincode Group default
Part Number RM22LA32MR
Rated current 8:00 AM
[Uc] control circuit voltage 24...240 V
[Us] rated supply voltage 24...240 V AC/DC 50/60 Hz
ambient air temperature for storage -40-70 °C
compatibility code RM22
connections - terminals screw connectors
contacts material cadmium free
IP degree of protection IP20 (terminals) conforming to IEC 60529, IP40 (housing) conforming to IEC 60529, IP50 (front panel) conforming to IEC 60529
maximum switching voltage 250 V AC
mechanical durability 10000000 cycles
minimum switching current 10 mA at 5 V DC
mounting position any position
mounting support 35 mm DIN rail conforming to EN/IEC 60715
net weight 0.11 kg
overvoltage category III conforming to IEC 60664-1
pollution degree 3 conforming to IEC 60664-1
product certifications UL, RCM, CSA, GL, CCC, CE, EAC
product or component type level control relay
range of product Harmony Control Relays
relative humidity 93-97 % at 25-55 °C conforming to IEC 60068-2-30
shock resistance 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27, 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
supply voltage limits 20.4-264 V AC/DC
tightening torque 0.6-1 N.m conforming to IEC 60947-1
utilisation category AC-15 conforming to IEC 60947-5-1, DC-13 conforming to IEC 60947-5-1, AC-1 conforming to IEC 60947-4-1, DC-1 conforming to IEC 60947-4-1
width 22.5 mm
contacts type and composition 2 C/O
Maximum power consumption in W 1.5 W DC
Immunity to microbreaks 100 ms DC, 90 ms AC
Measurement error < 1 % over the whole range with voltage variation, 0.05 %/°C with temperature variation
Switching capacity in VA 2000 VA
Nominal output current 8:00 AM
Housing material self-extinguishing plastic
Time delay type adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
Repeat accuracy +/- 2 % for time delay
Maximum switching current 8 A AC
Functionality resistive probe detection
Maximum cable distance between devices 1000 m between probe and delay
Output contacts 2 C/O
Dielectric test voltage 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
Relay monitored parameters detection by resistive probes
Relay name RM22L
Relay type level control relay
Run-up delay at power-up 2.5 s, 0.6 s
Cable capacitance 1 nF at HS (High Sensitivity) for probe cable, 2.2 nF at St (Standard Sensitivity) for probe cable, 4.7 nF at LS (Low Sensitivity) for probe cable
Sensitivity scale 0.25...5 kOhm LS (Low Sensitivity), 5...100 kOhm St (Standard Sensitivity), 50...1000 kOhm HS (High Sensitivity)
Sensitivity adjustment 5-100 %
Maximum electrode voltage 12 V AC
Maximum electrode current 1 mA
Maximum supply current for sensors 1 mA
vibration resistance 0.075 mm (f= 10-58.1 Hz) not in operation conforming to IEC 60068-2-6, 1 gn (f= 10-58.1 Hz) not in operation conforming to IEC 60068-2-6, 0.035 mm (f= 58.1-150 Hz) in operation conforming to IEC 60068-2-6, 0.5 gn (f= 58.1-150 Hz) in operation conforming to IEC 60068-2-6
electromagnetic compatibility immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1, immunity for industrial environments conforming to EN/IEC 61000-6-2, emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3, emission standard for industrial environments conforming to EN/IEC 61000-6-4, electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2, electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2, radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3, electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4, electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4, surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5, surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5, conducted and radiated emissions class B group 1 conforming to CISPR 11, conducted and radiated emissions class B conforming to CISPR 22
standards EN/IEC 60255-1
safety reliability data MTTFd = 182.6 years, B10d = 170000
Insulation between supply and measurement
Electrical Durability 100000 cycles

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: Level control relay RM22-L - 24..240 V AC/DC - 2 C/O
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.