EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 65A - 220 V AC coil

LC1E65M7
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Product Details

Activity PPCTR
Price AED 427.64
Pincode Group default
Part Number LC1E65M7
[Ith] conventional free air thermal current 80 A (at 55 °C)
[Uc] control circuit voltage 220 V AC 50/60 Hz
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV coil not connected to the power circuit conforming to IEC 60947
associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1, 125 A gG at <= 690 V coordination type 1 for power circuit
auxiliary contact composition 1 NO + 1 NC
average impedance 1 mOhm - Ith 80 A 50 Hz for power circuit
connections - terminals control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: solid without cable end
contactor application resistive load, motor control
control circuit type AC at 50/60 Hz
control circuit voltage limits 0.85...1.1 Uc (55-55 °C):operational 50/60 Hz, 0.3...0.6 Uc (55-55 °C):drop-out 50/60 Hz
depth 114 mm
device short name LC1E
fire resistance 850 °C conforming to IEC 60695-2-1
heat dissipation 6-10 W for control circuit
height 127 mm
hold-in power consumption in VA 15-15 VA 50 Hz cos phi 0.3 (at 20 °C), 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
inrush power in VA 160-160 VA 50 Hz cos phi 0.75 (at 20 °C), 140-140 VA 60 Hz cos phi 0.75 (at 20 °C)
IP degree of protection IP2X conforming to IEC 60529
Irms rated making capacity 650 A at 440 V AC for power circuit conforming to IEC 60947-4-1
maximum operating rate 1200 cyc/h 60 °C
mechanical durability 5000000 cycles
minimum switching current 5 mA for control circuit
minimum switching voltage 17 V for control circuit
motor power kW 18.5 kW at 220...230 V AC 50/60 Hz, 30 kW at 380...400 V, 37 kW at 415 V, 37 kW at 440 V, 37 kW at 500 V, 37 kW at 660...690 V
mounting support DIN rail, plate
net weight 0.98 kg
non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact, 1.5 ms on de-energisation guaranteed between NC and NO contact
operating altitude 3000 m without derating
operating time 20...26 ms on closing, 8...12 ms on opening
overvoltage category III
permissible ambient air temperature around the device -20-70 °C at Uc, -60-80 °C storage, -5-55 °C operation
pole contact composition 3 NO
Poles Description 3P
pollution degree 3
power dissipation per pole 4.2 W AC-3, 6.4 W AC-1
product certifications EAC, CE
product or component type contactor
protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30 test Db
range EasyPact
rated breaking capacity 520 A at 440 V for power circuit conforming to IEC 60947
rated operational voltage limits power circuit: <= 690 V AC 50/60 Hz
tightening torque control circuit: 1.2 N.m, power circuit: 5 N.m
utilisation category AC-1, AC-3
width 75 mm
[Icw] rated short-time withstand current 520 A 40 °C - 10 s for power circuit, 260 A 40 °C - 60 s for power circuit, 110 A 40 °C - 600 s for power circuit
standards IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1
[Ie] rated operational current 65 A (at <55 °C) at <= 440 V AC AC-3 for power circuit, 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
insulation resistance > 10 MOhm for control circuit
mechanical robustness vibrations contactor open (1.5 Gn, 5...300 Hz) , vibrations contactor closed (3 Gn, 5...300 Hz) , shocks contactor open (6 Gn for 11 ms) , shocks contactor closed (7 Gn for 11 ms)
Electrical Durability 350000 cycles AC-1, 900000 cycles AC-3

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 65A - 220 V AC coil
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

EasyPact TVS - auxiliary contact block - 1 NO + 1 NC - screw-clamps terminals
LAEN11

In stock

AED 12.25
AED 26.31
EasyPact TVS - auxiliary contact block - 2 NO + 2 NC - screw-clamps terminals
LAEN22

In stock

AED 24.12
AED 51.64
EasyPact TVS - auxiliary contact block - 2 NO - screw-clamps terminals
LAEN20

In stock

AED 12.40
AED 26.31
EasyPact TVS - time delay - on delay - 1 NO + 1 NC
LAETSD

In stock

AED 75.14
AED 202.47
EasyPact TVS - mechanical interlock - for LC1E06…E65
LAEM1

In stock

AED 45.00
AED 74.83
EasyPact TVS - auxiliary contact block - 2 NC - screw-clamps terminals
LAEN02

In stock

AED 12.30
AED 26.31