Activity |
SP |
Price |
AEDÂ 11,175.00 |
Pincode Group |
default |
Part Number |
SRVS10KIL |
Acoustic Level |
58 dBA |
Additional Information |
Configurable for 220 : 230 or 240 nominal output voltage |
Alarm |
alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
ambient air temperature for storage |
-15-60 °C |
Battery Charger Power |
1170 W rated |
Battery Curve |
D |
Battery Design Life |
2 year(s) |
Battery Life |
3-5 year(s) |
Battery Option |
SRVS240BP-9A 1 3024 VAh , SRVS240BP-9A 2 4536 VAh , SRVS240BP-9A 3 6048 VAh , SRVS240BP-9A 4 7560 VAh |
Battery Power in Vah |
1512 VAh runtime |
Battery Recharge Time |
5 h |
Battery Type |
lead-acid battery |
Battery Voltage |
240 V |
Bypass Type |
internal bypass (automatic and manual) |
colour |
black (RAL 7010) |
Control Panel |
multifunction LCD status and control console |
Crest Factor |
03:01 |
Curve Equation |
efficiency |
Curve Fixed Loss |
0.0179 |
Curve Load Maximum |
100% |
Curve Load Minimum |
2% |
Curve Proportional Loss |
-0.016 |
Curve Square Loss |
0.0624 |
Curve Test Cond Id |
Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output. |
depth |
48.5 cm |
efficiency |
94 % (full load) |
Emergency Power Off |
yes |
Free Slots |
1 |
Graph Display |
1 |
heat dissipation |
2128 Btu/h |
height |
36.8 cm |
input voltage |
220 V, 240 V |
input voltage limits |
110...300 V half load, 176...300 V full load |
IP degree of protection |
IP20 |
Liquid Value |
0 |
Maximum Configurable Power in Va |
10000 VA |
Maximum Configurable Power in w |
10000 W |
Mounting Location |
front |
mounting mode |
not rack-mountable |
mounting position |
vertical |
Mounting Preference |
no preference |
net weight |
76.5 kg |
network frequency |
40...70 Hz auto sensing |
Number of Battery Filled Slots |
0 |
Number of Battery Free Slots |
0 |
Number of Input Connectors |
1 hard wire 3-wire (1P + N + E) |
Number of Power Module Filled Slots |
0 |
Number of Power Module Free Slots |
0 |
Number of Tare Power |
70 W |
operating altitude |
0...3000 m |
Output Connector Type |
hard wire 3-wire (1P + N + E) 1 |
Output Frequency |
50/60 Hz +/- 3 Hz sync to mains |
output voltage |
220 V, 240 V |
product certifications |
CE, UKCA |
Provided Equipment |
1 USB cable, 1 RS-232 configuration cable, 1 external battery pack, 1 battery cable, 1 user manual |
Rated Power in Va |
10000 VA |
rated power in W |
10000 W |
Redundant |
No |
relative humidity |
0-95 % non-condensing |
Show Note Op Temperature |
No |
Storage Altitude |
0-15000 m |
Storage Relative Humidity |
0-95 % non-condensing |
Surge Energy Rate |
600 J |
Ups Design Life |
3 year(s) |
Ups Size |
WS |
Ups Type |
double conversion online |
Usb Compatible |
Yes |
Wave Type |
sine wave |
width |
38 cm |
Curve X-axis Maximum |
100% |
Curve X-axis Minimum |
0% |
Curve X-axis Title |
load |
Curve X-axis Units |
percentage |
Curve Y-axis Maximum |
100% |
Curve Y-axis Minimum |
50% |
Curve Y-axis Title |
efficiency |
Curve Y-axis Units |
percentage |
Main Input Voltage |
230 V |
ambient air temperature for operation |
0-40 °C |
standards |
EN/IEC 62040-1:2019/A11:2021, EN/IEC 62040-2:2006/AC:2006, EN/IEC 62040-2:2018 |