controller M221 24 IO relay

TM221C24R
Be the first one to review this.
login_green To View the best prices please Sign in / Register.
Only 0 left in stock.
plain-icon

Product Details

Activity IDMST
Resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2, 4 kV on contact conforming to EN/IEC 61000-4-2
Price AED 1,512.04
Pincode Group default
Part Number TM221C24R
ambient air temperature for storage -25-70 °C
depth 70 mm
supply voltage limits 85-264 V
width 110 mm
Discrete output current 2:00 AM
Supply (serial)serial link supply: 5 V, <200 mA
Data backed up 256 kB built-in flash memory for backup of application and data
Data storage equipment 2 GB SD card (optional)
Reset time 1 s
Clock drift <= 30 s/month at 25-25 °C
Immunity to microbreaks 10 ms
Discrete input current 7 mA for discrete input, 5 mA for fast input
Voltage state 1 guaranteed >= 15 V for input
Discrete input voltage 24 V
Backup time 1 year at 25 °C (by interruption of power supply)
Voltage state 0 guaranteed <= 5 V for input
Discrete input number 14 , discrete input conforming to IEC 61131-2 Type 1
Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3, 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3, 1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
Surge withstand 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5, 2 kV relay output common mode conforming to EN/IEC 61000-4-5, 1 kV I/O common mode conforming to EN/IEC 61000-4-5, 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5, 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5, 1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5, 1 kV relay output differential mode conforming to EN/IEC 61000-4-5, 0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
Resistance to fast transients 2 kV (power lines) conforming to EN/IEC 61000-4-4, 2 kV (relay output) conforming to EN/IEC 61000-4-4, 1 kV (I/O) conforming to EN/IEC 61000-4-4, 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4, 1 kV (serial link) conforming to EN/IEC 61000-4-4
Electromagnetic emission conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15-0.5 MHz conforming to EN/IEC 55011, conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5-300 MHz conforming to EN/IEC 55011, conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10-150 kHz conforming to EN/IEC 55011, conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5-30 MHz conforming to EN/IEC 55011, radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to EN/IEC 55011, conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150-1500 kHz conforming to EN/IEC 55011, radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200-1000 MHz conforming to EN/IEC 55011
Analogue input resolution 10 bits
Analogue input number 2 at 0...10 V
Permitted overload on inputs +/- 30 V DC for 5 min (maximum) for analog input, +/- 13 V DC (permanent) for analog input
Discrete output type relay normally open
LSB value 10 mV
Conversion time 1 ms per channel + 1 controller cycle time for analogue input analog input
Discrete output number 10 relay
Sensor power supply 24-24 V DC at 250 mA supplied by the controller
Realtime clock with
Discrete input logic sink or source (positive/negative)
Discrete input voltage type DC
Maximum number of I/O expansion module 7 for transistor output, 7 for relay output
Counting input number 4 fast input (HSC mode) at 100 kHz 32 bits
Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6, 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL), 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Maximum cable distance between devices shielded cable: <10 m for fast input, unshielded cable: <30 m for output, unshielded cable: <30 m for digital input, unshielded cable: <1 m for analog input
Maximum current per output common 4 A at COM 2, 7 A at COM 0, 7 A at COM 1
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15-15 m for RS485, 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3-3 m for RS232, 480 Mbit/s for USB
Discrete I/O number 24
Configurable filtering time 0 ms for input, 3 ms for input, 12 ms for input
Discrete output voltage 5...125 V DC, 5...250 V AC
Memory capacity 256 kB for user application and data RAM with 10000 instructions, 256 kB for internal variables RAM
Execution time for 1 KInstruction 0.3 ms for event and periodic task
Absolute accuracy error +/- 1 % of full scale for analog input
Resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
Maximum power consumption in VA 55 VA at 100...240 V with max number of I/O expansion module, 32 VA at 100...240 V without I/O expansion module
Regulation loop adjustable PID regulator up to 14 simultaneous loops
Exct time for event task 60 µs response time
Execution time per instruction 0.2 µs Boolean
Maximum size of object areas 255 %C counters, 8000 %MW memory words, 512 %M memory bits, 512 %KW constant words, 255 %TM timers
Minimum load 1 mA at 5 V DC for relay output
vibration resistance 3.5 mm at 5-8.4 Hz on symmetrical rail, 3.5 mm at 5-8.4 Hz on panel mounting, 1 gn at 8.4-150 Hz on symmetrical rail, 1 gn at 8.4-150 Hz on panel mounting
ambient air temperature for operation -10-55 °C (horizontal installation), -10-35 °C (vertical installation)
standards EN/IEC 61010-2-201, EN/IEC 60664-1, EN/IEC 61131-2
Storage Altitude 0-3000 m
Communication Port Protocol USB port: USB - SoMachine-Network, non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network
Control Signal Type A/B, single phase, pulse/direction
Switching Frequency 20 switching operations/minute with maximum load
Electrical Durability 100000 cycles AC-12, 120 V, 240 VA, resistive, 100000 cycles AC-14, cos phi = 0.7 , 240 V, 240 VA, inductive, 300000 cycles AC-14, cos phi = 0.7 , 120 V, 36 VA, inductive, 300000 cycles AC-14, cos phi = 0.7 , 240 V, 72 VA, inductive, 100000 cycles DC-12, 24 V, 48 W, resistive, 300000 cycles DC-12, 24 V, 16 W, resistive, 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms), 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms), 100000 cycles AC-12, 240 V, 480 VA, resistive, 300000 cycles AC-12, 120 V, 80 VA, resistive, 300000 cycles AC-12, 240 V, 160 VA, resistive, 100000 cycles AC-15, cos phi = 0.35 , 120 V, 60 VA, inductive, 100000 cycles AC-15, cos phi = 0.35 , 240 V, 120 VA, inductive, 300000 cycles AC-15, cos phi = 0.35 , 120 V, 18 VA, inductive, 300000 cycles AC-15, cos phi = 0.35 , 240 V, 36 VA, inductive, 100000 cycles AC-14, cos phi = 0.7 , 120 V, 120 VA, inductive

Seller Information

Documents

Extended Warranty

Reviews

Write Your Own Review
You're reviewing: controller M221 24 IO relay
* Required Field
loader
Loading...

check-circle You submitted your review for moderation.

Frequently Bought Together

cartridge M221 - 1 serial line - communication extension
TMC2SL1

In stock

AED 144.95
AED 231.21
cartridge M221 - 2 analog voltage outputs - I/O extension
TMC2AQ2V

In stock

AED 226.00
AED 319.29
graphic display unit - 240 x 160 pixels
TMH2GDB

In stock

AED 654.00
AED 924.84